The London Sash Window Company Limited is a Penge-based joinery installation business incorporated in January 2006. It offers surveys, refurbishment and replacement of period windows, serving domestic and commercial properties across London and surrounding districts.
Its published Mayfair refurbishment case study documents work to existing sash and casement windows in serviced apartments, including repairs to decayed timber and glazing, servicing and draught reduction without full replacement. This provides a specific example of its repair capability alongside its replacement window business.
For historic properties, owners should request a condition-led assessment with separate repair and replacement options, identifying retained frames, historic glass, glazing bars and ironmongery. The company is listed on the FENSA installer register; this is evidence of installation scheme registration, not specialist conservation accreditation.
Inclusion in the directory is editorial and does not constitute endorsement. Confirm relevant experience, insurance, specification and statutory approvals before commissioning work.
| Service Overview | |
|---|---|
| ConserveConnect Guide to the Specialism: | Traditional timber sash windows form an important part of London's architectural inheritance. Their glazing patterns, mouldings, counterbalance mechanisms, historic glass and relationship to brickwork and stucco distinguish buildings of different periods and contribute to the coherence of whole streets. Their conservation protects surviving material and craft knowledge, not merely the outward appearance of a facade. Begin with a condition survey of each window. Examine sill ends, lower rails, joints, box linings, glazing putty, paint, cords, pulleys and weights. Identify moisture sources before repairing decay. Local timber splices, renewal of failed cords, rebalancing and compatible putty and coatings can often restore operation without wholesale replacement. Record historic glass and ironmongery and retain sound components wherever possible. Avoid indiscriminate stripping of significant finishes; assess hazards from old lead paint. Thermal upgrading should begin with maintenance and suitable measures to reduce uncontrolled draughts. Existing shutters and curtains can contribute to comfort. Secondary glazing can improve thermal and acoustic performance while preserving historic glass and joinery; its design should allow cleaning, maintenance and ventilation and avoid trapping moisture. Where secondary glazing is installed, consider the airtightness of the inner glazing and ventilation of the outer window assembly rather than sealing both indiscriminately. Slim-profile insulating glass may be appropriate where the existing glass is not significant and the sash can accommodate its thickness and weight without weakening glazing bars or changing profiles. Ask for sections showing rebates, putty lines and sightlines and consider the service life and future replacement of sealed units. Acoustic performance depends on the whole assembly, including seals and air gaps, not simply the glass specification. Compare repair and replacement on a whole-life basis, considering embodied carbon, material loss, maintenance and durability as well as operational energy. Keeping repairable windows supports local craft employment and avoids unnecessary consumption of timber and glass. Replacement should be justified by condition and significance, with profiles and materials compatible with the building. In London, listed building consent may be required for alterations affecting special interest; conservation area controls and Article 4 directions may restrict alterations to unlisted properties. Check the specific proposal with the relevant borough before work. Request a written schedule distinguishing repairs from replacements, details of retained material, examples of comparable work, insurance and guarantees, and a maintenance plan. ConserveConnect advocates conservation-led repair and responsible upgrading as part of the stewardship of historic homes and neighbourhoods. |
| Services & Expertise | |
| Principal Areas of Work: | Period houses, sash and casement windows, commercial properties |
| Capabilities and Specialisms: | Sash window repair Penge, South London, window refurbishment, traditional timber windows, draught-proofing |
| Accreditation & Membership Details: | FENSA registration 29366 verified in installer directory; not conservation accreditation. Other website badges not independently checked. |
| Geographical Areas Covered: | Greater London and surrounding areas including Surrey and parts of Kent; confirm availability. |
| Contact & Online Presence | |
| Mobile: | 07777 124314 |
| Email: | office@londonsash.com |
| Business Details & Assurance | |
| Company Trading Name: | The London Sash Window Company Limited |
| Company Number: | 05665961 |
| Publication & Verification | |
| Listing Content Supplied By: | ConserveConnect |
| Owner / Contributor Approval Status: | Not claimed |
| Information Last Checked: | 27/11/2026 |